{"product_id":"surgical-guide-resin-form-4-1-l","title":"Formlabs Surgical Guide Resin (Form 4) 1 L","description":"\u003cp\u003eSurgical Guide Resin is an autoclavable, biocompatible resin for 3D printing surgical guides, drilling templates, pilot drill guides, and device sizing templates that exceed dental demands in accuracy, part quality, and performance.\u003c\/p\u003e\n\n\u003cp\u003eSurgical Guide Resin was formulated specifically for Formlabs printers and rigorously tested to meet solvent disinfection and autoclave sterilisation standards for implant systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/dental.formlabs.com\/global\/indications\/surgical-guides\/\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eRead the application guide\u003c\/a\u003e to learn the complete digital workflow and best practices for making 3D printed surgical guides on your Formlabs 3D printer.\u003c\/p\u003e\n\n\u003cdiv style=\"margin: 24px 0;\"\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"text-align:left; padding:12px; border-bottom:1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"text-align:left; padding:12px; border-bottom:1px solid #ddd;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003ePrint Technology\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eSLA\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eBiocompatibility\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eSkin Contact, Mucosal Membrane Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eMinimum Layer Thickness\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003e50 micron\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eCategories\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eDental\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eColours\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eTranslucent\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eApplications\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eDental\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eFlexural Modulus\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003e2400.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eElongation at Break\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003e12.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eFlexural Strength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003e102.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin: 32px 0;\"\u003e\n  \u003ch2 style=\"margin-bottom:16px; padding-bottom:8px; border-bottom:1px solid #ddd; font-size:22px;\"\u003eCompatibility\u003c\/h2\u003e\n\n  \u003cp\u003e\u003cstrong\u003eCompatible Build Platform:\u003c\/strong\u003e Form 4 Build Platform, Form 4 Flex Build Platform, Form 3 Build Platform, Form 3 Build Platform 2, Form 3 Stainless Steel Build Platform, Form 3L Build Platform, Form 3L Build Platform 2L, Form 4L Build Platform, Form 4L Flex Build Platform\u003c\/p\u003e\n\n  \u003cp\u003e\u003cstrong\u003eCompatible Tank:\u003c\/strong\u003e Form 4 Resin Tank, Form 4L Resin Tank, Form 2 LT Tank, Form 3 Resin Tank V2.1, Form 3L Resin Tank V3\u003c\/p\u003e\n\n  \u003cp\u003e\u003cstrong\u003eCompatible Printer:\u003c\/strong\u003e Form 4B, Form 4BL, Form 3B, Form 3BL, Form 2\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin: 48px 0;\"\u003e\n  \u003ch2 style=\"font-size:28px; margin-bottom:12px;\"\u003eWhy Choose Surgical Guide Resin?\u003c\/h2\u003e\n\n  \u003cp\u003eSurgical Guide Resin provides dental professionals with a biocompatible material for the production of dimensionally accurate dental implant guides and templates.\u003c\/p\u003e\n\n  \u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit, minmax(220px, 1fr)); gap:20px; margin-top:24px;\"\u003e\n    \u003cdiv style=\"padding:20px; border:1px solid #ddd; border-radius:12px;\"\u003e\n      \u003ch3 style=\"margin-top:0;\"\u003eReliable\u003c\/h3\u003e\n      \u003cp\u003eConsistently produce reliable guides for digital dental workflows.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"padding:20px; border:1px solid #ddd; border-radius:12px;\"\u003e\n      \u003ch3 style=\"margin-top:0;\"\u003eEfficient\u003c\/h3\u003e\n      \u003cp\u003eLeverage a digital workflow from intraoral scanning to production.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"padding:20px; border:1px solid #ddd; border-radius:12px;\"\u003e\n      \u003ch3 style=\"margin-top:0;\"\u003eBiocompatible\u003c\/h3\u003e\n      \u003cp\u003eProvide the patient and clinician with the peace of mind they deserve.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin: 48px 0;\"\u003e\n  \u003ch2 style=\"font-size:28px; margin-bottom:12px;\"\u003eApplications\u003c\/h2\u003e\n\n  \u003cp\u003eSurgical Guide Resin is a premium-quality material for printing surgical implant guides.\u003c\/p\u003e\n\n  \u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit, minmax(220px, 1fr)); gap:20px; margin-top:24px;\"\u003e\n    \u003cdiv style=\"padding:20px; border:1px solid #ddd; border-radius:12px;\"\u003e\n      \u003ch3 style=\"margin-top:0;\"\u003eSplints\u003c\/h3\u003e\n      \u003cp\u003eCreate accurate dental splints for clinical workflows.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"padding:20px; border:1px solid #ddd; border-radius:12px;\"\u003e\n      \u003ch3 style=\"margin-top:0;\"\u003eDevice Sizing Templates\u003c\/h3\u003e\n      \u003cp\u003eProduce templates to support accurate device sizing and planning.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"padding:20px; border:1px solid #ddd; border-radius:12px;\"\u003e\n      \u003ch3 style=\"margin-top:0;\"\u003eOcclusal Guards\u003c\/h3\u003e\n      \u003cp\u003ePrint dental guards for approved clinical workflows where applicable.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"padding:20px; border:1px solid #ddd; border-radius:12px;\"\u003e\n      \u003ch3 style=\"margin-top:0;\"\u003eDrilling Templates\u003c\/h3\u003e\n      \u003cp\u003eProduce drilling templates and pilot drill guides for implant planning.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin: 48px 0; padding:24px; border:1px solid #ddd; border-radius:12px;\"\u003e\n  \u003ch2 style=\"font-size:24px; margin-top:0;\"\u003eManufactured in an ISO 13485-Certified Facility\u003c\/h2\u003e\n  \u003cp\u003eFormlabs manufactures its BioMed and Medical Device Resins at its FDA-registered facility in Ohio. These materials are designed and manufactured within a robust Quality Management System that is ISO 13485 and EU MDR certified.\u003c\/p\u003e\n  \u003cp\u003eA dedicated team of operators and quality assurance professionals makes the resins inside a certified ISO Class 8 clean room. All Formlabs Medical Device Resins are appropriately registered with the FDA and CE marked according to the EU MDR.\u003c\/p\u003e\n  \u003cp\u003e\u003ca href=\"https:\/\/media.formlabs.com\/m\/d5be5e72af5a1f5\/original\/-ENUS-ISO-Certificate-of-Registration.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eView Our Certification\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin: 48px 0;\"\u003e\n  \u003ch2 style=\"font-size:28px; margin-bottom:12px;\"\u003eMaterial Properties*\u003c\/h2\u003e\n\n  \u003cp\u003e\u003ca href=\"https:\/\/formlabs.com\/uk\/materials\/data-sheets\/?product=surgicalguide\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload the Surgical Guide Resin Technical Data Sheet\u003c\/a\u003e\u003c\/p\u003e\n\n  \u003cdiv style=\"margin-top:24px;\"\u003e\n    \u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth style=\"text-align:left; padding:12px; border-bottom:1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n          \u003cth style=\"text-align:left; padding:12px; border-bottom:1px solid #ddd;\"\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eElongation\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003e12%\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eFlexural Strength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003e\u0026gt; 102 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003eFlexural Modulus\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px; border-bottom:1px solid #eee;\"\u003e\u0026gt; 2400 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003cp style=\"font-size:12px; margin-top:20px;\"\u003e*Material properties may vary based on part geometry, print orientation, print settings, and temperature. Data for post-cured samples were measured on Type IV tensile bars printed on a Form 2 printer with 100 μm Surgical Guide Resin settings, washed in a Form Wash for 20 minutes in ≥99% isopropyl alcohol, and post-cured at 60 °C for 30 minutes in a Form Cure.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin: 48px 0;\"\u003e\n  \u003ch2 style=\"font-size:28px; margin-bottom:12px;\"\u003ePost-Processing\u003c\/h2\u003e\n\n  \u003cp\u003e\u003ca href=\"https:\/\/media.formlabs.com\/m\/3539f9962e77357f\/original\/EN-Surgical-Guide-Resin-Instructions-for-Use.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction for Use: Surgical Guide Resin\u003c\/a\u003e\u003c\/p\u003e\n\n  \u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit, minmax(280px, 1fr)); gap:24px; margin-top:24px;\"\u003e\n    \u003cdiv style=\"padding:20px; border:1px solid #ddd; border-radius:12px;\"\u003e\n      \u003ch3 style=\"margin-top:0;\"\u003eWashing\u003c\/h3\u003e\n      \u003cp\u003eSurgical Guide Resin may be washed using either a Formlabs-validated wash unit or an ultrasonic wash unit.\u003c\/p\u003e\n      \u003cp\u003eThe foundational step in any SLA post-processing workflow is to remove excess resin on the surface of the parts through an alcohol wash. Please refer to the material's manufacturing guide\/IFU for washing instructions.\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003eSettings:\u003c\/strong\u003e \u003ca href=\"https:\/\/media.formlabs.com\/m\/7a650152ce74f470\/original\/ENUS-Surgical-Guide-Resin-Manufacturing-Guide.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManufacturing Guide\u003c\/a\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"padding:20px; border:1px solid #ddd; border-radius:12px;\"\u003e\n      \u003ch3 style=\"margin-top:0;\"\u003eCuring\u003c\/h3\u003e\n      \u003cp\u003eFor biocompatible materials, post-curing is necessary to achieve the safety standards determined by regulatory agencies. Please follow the material’s manufacturing guide\/IFU for proper post-processing.\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003eSettings:\u003c\/strong\u003e \u003ca href=\"https:\/\/media.formlabs.com\/m\/7a650152ce74f470\/original\/ENUS-Surgical-Guide-Resin-Manufacturing-Guide.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManufacturing Guide\u003c\/a\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Formlabs","offers":[{"title":"Default Title","offer_id":56895279923582,"sku":"RS-C2-SGAM-01","price":252.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0608\/9464\/2434\/files\/CMS_Optimized_PNG-F41L_SURGICAL_GUIDE_V1_RESIN_SPINE_LABEL_01_no_shadow.png?v=1783590574","url":"https:\/\/evo3d.co.uk\/products\/surgical-guide-resin-form-4-1-l","provider":"Evo3D","version":"1.0","type":"link"}